Process Pumps – The Pump selection is important for the overall economy.
In connection with finding the best pump for a given task, the desired flow and information on the required head are decisive for the pump selection.
With IWAKI’s huge pumping experience, you can be sure that we deliver a pump with optimized power consumption, no matter what needs pumping.
- Small power consumption
- Small operating costs
- Small environmental impact
Most IWAKI pumps are used for tasks with aggressive, flammable and toxic fluids. At IWAKI we always take into account eg. the density of the liquid, viscosity and suction conditions at the given liquid temperature.
Example – 1000 liters of hydrochloric acid / min
The following example is based on a customer enquiry for a pump for 1000 liters of hydrochloric acid (HCl ≤38%) per minute with a max. head of about 20 meters.
The pump type / size chosen for the purpose is the MDM50 which manages the task with an 130 mm impeller and a power consumption of app. 7,3 kW. As standard we can deliver a 7,5 kW motor. In this case, there is no reason to choose a more powerful engine, as it will only mean higher operating costs and an increased environmental impact. A smaller engine will not be able to handle the task.
Pump Type | Required Flow | Head | Impeller | Power Consumption | Performance Curves |
MDM50-1101 | 1000 l/min | 11,0 m | 110 mm | 5,1 kW | Click here |
MDM50-1201 | 1000 l/min | 15,5 m | 120 mm | 6,1 kW | Click here |
MDM50-1301 | 1000 l/min | 20,0 m | 130 mm | 7,3 kW | Click here |
MDM50-1401 | 1000 l/min | 24,5 m | 140 mm | 8,3 kW | Click here |
MDM50-1501 | 1000 l/min | 28,5 m | 150 mm | 9,6 kW | Click here |
MDM50-1601 | 1000 l/min | 33,0 m | 160 mm | 10,7 kW | Click here |
MDM50-1651 | 1000 l/min | 36,0 m | 165 mm | 11,5 kW | Click here |
Example at desired flow rate of 1000 l / min (HCl).