• English
  • Dansk
  • Suomi
  • Norsk Bokmål
  • Svenska

Contact us on +45 4824 2345

IWAKI Nordic

The Heart of Industry

  • Home
  • Products
    • Process
      • Magnetic Drive Pumps in Fluoroplastics / Polypropylene
      • Magnetic Drive Pumps in Stainless Steel
      • Drum pumps
      • AODD pumps
    • Dosing
      • Electromagnetic metering pumps
      • Motor driven metering pumps
      • Gear pumps
      • Dosing Units
      • Dosing Panels
      • Dosing Cabinets
    • OEM Pumps
      • Rotary displacement pumps
      • Air pumps
      • Magnetic drive gear pumps
      • Bellows pumps
      • Electromagnetic metering pumps
      • Magnetic drive pumps
    • Systems
      • Dosing cabinets
      • Safety cabinets
      • Mobile units
      • Process units
      • Process equipment
      • Basic safety
      • Tanks
    • Mixers & Agitators
      • Mixers for IBC Pallet Tanks and Barrels
      • Gear Drive Agitators
      • Special Mixers and Agitators
      • Stands and Lifting Equipment
    • Process Control
    • FDA-certified pumps
      • Tanks for food and pharma industries
    • ATEX pumper
      • ATEX pumps from IWAKI Nordic A/S
      • In general | ATEX – Categories and ATEX-zones
      • In general | ATEX – Product marking
    • Technology & Tips
  • Download
    • Videos
    • Process
      • Brochures
      • Instruction manuals
      • Performance curves
      • Spare parts
    • Dosing
      • Brochures
      • Instruction manuals
      • Spare parts
    • OEM
      • Brochures
      • Instruction manuals
      • Performance curves
      • Spare parts
    • Systems
      • Brochures
      • Instruction manuals
      • Spare parts
  • Quality & Service
    • Safety & Durability
    • Satisfaction Guaranteed
    • Safety Guarantee
    • Service
    • Certificates
  • Stock
    • Repair & Service
  • About
    • Finding the way
    • Mission Statement
    • Samhandelsbetingelser
    • Code of Conduct
    • Policy Statement on Conflict Minerals
    • Sustainable Development
    • IWAKI Pumps in the early days
    • IWAKI Nordic – Group
    • News
  • Contact
    • Employees
    • Northern Europe
    • America
    • Europe
    • Asia
    • Australia
    • Distributors
You are here: Home / Home / Products / Dosing / Motor driven metering pumps / IX-B Series

Dosing Pumps — IX-B Series

ix-serien

IX-B Series – Metering pumps

High efficiency brushless motor driven diaphragm type metering pump 

  • Unique drive design:
    The IX-B pumps use brushless DC (BLDC) motors to control the pump stroke speed. The efficiency of the BLDC motor provides a high power output in a small package and allows the IX-B pumps to achieve 45L/H discharge flowrates.
  • High Turndown Ratio:
    The turndown ratio of the IX-B series improves to 1000:1 via stroke rate control by the BLDC motor.
  • High Accuracy:
    The pumps are +-1% repeatable across most of the control range. Minimum flow of the IX-B series is 0.0075L/H.
  • Degassing valve unit design:
    Due to the proprietary valve unit design the IX series pumps provides excellent degassing ability. The IX-B pumps retain this feature creating an entire pump line that will not gas lock and has no priming issues.
  • Improved chemical resistance:
    Liquid End materials in PVDF or SUS316, a highly chemical resistance material, and a choice of elastomers (FKM or EPDM). New is a non-elastomer, solid PTFE diaphragm providing optimal resistance to chemical gas penetration and better allround chemical resistance.
  • Flexible installation:
    The IX-B pumps unique design enables the pumps to be installed in various locations. The control unit can easily be repositioned by customers onsite. The pump base can also be relocated for PVDF models and wall mounted without any extra parts required. Tubing, threaded, flanged or union (Georg Fischer) connections are available as standard options providing easy installation for any application.

ix-serien

Specifications

Model Max flow
l/h
Max pressure
MPa
Power
Consumption
Watt
Current
Amps
Connection
Size
Weight Kg
IX-B007 TC/TE 0.0075 – 7.5 1.7 17W 0.4A R1/2 3.5
IX-B007 TC/TE ½NPT 3.5
IX-B007 TC/TE G3/4 3.5
IX-B007 S6 R3/8 4.5
IX-B007 S6 3/8FNPT 4.5
IX-B007 TC/TE 1.7 note1 RTPI note2 3.5
IX-B007 TC/TE 1.0 DIN PN10 DN15 JIS, ANSI note3 3.7
IX-B007 S6 DIN PN10 DN15 JIS, ANSI note3 6.0
IX-B015 TC/TE 0.015 – 15 1.0 17W 0.4A R1/2 3.5
IX-B015 TC/TE ½NPT 3.5
IX-B015 TC/TE G3/4 3.5
IX-B015 S6 R3/8 4.5
IX-B015 S6 3/8FNPT 4.5
IX-B015 TC/TE 1.0 note1 RTPI note2 3.5
IX-B015 TC/TE 1.0 DIN PN10 DN15 JIS, ANSI note3 3.7
IX-B015 S6 DIN PN10 DN15 JIS, ANSI note3 6.0
IX-B030 TC/TE 0.03 – 30 0.6 19W 0.5A R1/2 3.7
IX-B030 TC/TE ½NPT 3.7
IX-B030 TC/TE G3/4 3.7
IX-B030 S6 R3/8 5.0
IX-B030 S6 3/8FNPT 5.0
IX-B030 TC/TE 0.6 note1 RTPI note2 3.7
IX-B030 TC/TE 0.6 DIN PN10 DN15 JIS, ANSI note3 3.9
IX-B030 S6 DIN PN10 DN15 JIS, ANSI note3 6.5
IX-B045 TC/TE 0.045 – 45 0.4 19W 0.5A R1/2 3.7
IX-B045 TC/TE ½NPT 3.7
IX-B045 TC/TE G3/4 3.7
IX-B045 S6 R3/8 5.0
IX-B045 S6 3/8FNPT 5.0
IX-B045 TC/TE 0.4 note1 RTPI note2 3.7
IX-B045 TC/TE 0.4 DIN PN10 DN15 JIS, ANSI note3 3.9
IX-B045 S6 DIN PN10 DN15 JIS, ANSI note3 6.5

note1: Use below the maximum allowable pressure of a connected tube.
note2: Please refer to pump identification.
note3: JIS 10K 15A, DIN PN10 DN15, ANSI 150Lb 1/2″.

  • The above is the value at rated voltage, ambient temperature and clean water.
  • Liquid temperature range: 0 -50°C (TC, TE) and 0 -80°C (SUS316) (No viscosity change. Non freezing. No slurry)
  • Maximum viscosity: with standard valve up to 500 mpA•s / with viscous valve up to 1000 mPa•s.
  • The pressure at which the abnormal pressure detection function operates is 1.3 to 2 times the maximum discharge pressure.
  • Allowable voltage fluctuation: within ±10% of the rated voltage.
  • Operating ambient temperature: 0-50°C
  • Operating humidity range: 30-90% RH (Non-condensing in the controller)
  • Flanges will be shared with the standards listed in the table.
  • Maximum priming lift is 1-2m depending on model.
  • High accuracy ±1% (it becomes ±0.3mL/h when it is set to 30 mL/h or less.
  • Liquid end materials in PVDF or SUS316
  • Controller options: analog, pulse, batch, profibus etc. (See brochure)

Download

Brochure Instruction manual Spare parts lists

The pump also comes built-in

Dosing Cabinets Safety Cabinets Dosing Units Mobile Units
  • Process
  • Dosing
  • OEM Pumps
  • Systems
  • Mixers & Agitators
  • Process Control
  • FDA-certified pumps
  • ATEX Pumps
  • Technology & Tips
  • Safety & Durability
  • Satisfaction Guaranteed
  • Safety Guarantee
  • Service
  • Certificates
  • Repair & Service
  • Contact
  • Employees
  • Northern Europe
  • America
  • Europe
  • Asia
  • Australia
  • Distributors
  • Finding the way
  • Mission Statement
  • Terms & Conditions
  • Code of Conduct
  • Policy Statement on Conflict Minerals
  • Sustainable Development
  • IWAKI Nordic – Group
  • IWAKI Pumps in the early days
  • News
  • Videos
  • Process
  • Dosing
  • OEM
  • Systems

Copyright © 2023 - Cookies- and privacy policy: EN DA FI SV NO