Dosing pumps – IX Series, Model C & D
A new generation of advanced metering pump technology!
- High Turndown Ratio – Motor control adjusts the discharge and suction speeds to meet a full and accurate turndown ratio of 750:1
- High Accuracy – Combined with precise motor control, an efficient valve design maintains accurate flow rates allowing a low cost, mechanically-driven diaphragm pump to achieve a high accuracy of ±1%
- Energy Savings – Helical gears and return springs reduce power consumption by up to 70% compared to conventional motor-driven mechanical diaphragm metering pumps
- High Compression Pump Head Design – A fixed stroke length maintains a high compression ratio in each stroke resulting in fast priming and no air-lock at any flow rate
- Flexible, User-friendly Interface – The controller position can be ordered in 6 positions for operator convenience and ease of use after installation
- Food and pharmaceutical industries – IX-C150S6 pumps are approved according to EC1935/2004 for use in the food industry and in the pharmaceutical industry.
Technical data (50Hz)
Model | Max Flow l/h |
Max Pressure MPa |
Avarage Power Consumption |
Current Amps |
Connection Size |
Weight Kg | |
IX-C060 | TC/TE | 0.08 – 60 l/h | 1.0 MPa | 62W | 0.8A | 1/2″ NPT | 9.0 |
IX-C060 | S6 | 12.0 | |||||
IX-C150 | TC/TE | 0.2 – 150 l/h | 0.4 MPa | 3/4″ NPT | 9.0 | ||
IX-C150 | S6 | 13.0 | |||||
IX-D150 | TC/TE | 0,2 – 150 l/h | 1.0 MPa | 110W | 1.3A | 3/4″ NPT | 14.5 |
IX-D150 | S6 | 15.0 | |||||
IX-D300 | TC/TE | 0,4 – 300 l/h | 0.5 MPa | 1″ NPT | 15.5 | ||
IX-D300 | S6 | 17.0 |
- Maximum discharge capacity is rated with clean water at ambient temperature at maximum discharge pressure. Output may increase as pressure decreases
- Maximum viscosity :IX-C: 1000 cps IX-D: 300 cps (standard pumps – consult factory for higher viscosities)
- Liquid temperature range: 0 -50°C (TC, TE type), 0-80°C (S6 type). No viscosity change. Non freezing. No slurry.
- Operating temperature range: 0-50°C (Indoor use only)
- Operating humidity range: 0-90% RH (Non-condensing in the controller)
- Maximum dry suction lift is 6.5 ft. (2m).
- Accuracy is not guaranteed at flows below 0.5GPH (2 LPH) for IX-D300S6, 0.26GPH (1 LPH) for IX-C150S6 or 0.11GPH (0.4 LPH) for IX-C060S6.
- Pumps should always be shielded from direct exposure to the elements
- Materials: PVDF or AISI316
- Control: mA, batch, Profibus
- Multi Voltage: 100-240V